myQA® Daily - easy, efficient, accurate by design
myQA Daily is the only solution for fast, easy, and
high-quality morning Linac QA.
The largest number of ionization chambers provides more
beam data for more accurate beam quality verification.
The web-browser-based myQA Daily application allows
flexible test execution from any network PC or tablet and easy access to
test results.
The newest solution for daily QA
Easy
- Efficient – Accurate
· 1
minute cable free setup
· 1 test
run for dose & energy
· 1 click
analysis
Compatible with all standard Linacs
Blue Phantom 2
3D
Water Phantom System for
complete
Linac Commissioning & QA
The Blue Phantom² embodies decades of expertise, research and
experience, providing you with the best of water phantoms.
- Precision: Unique absolute
measurement technology
- Long-term accuracy: High-precision,
non-contact position sensor technology w/o non-mechanical wear
- Positioning: Detector
positioning certified to ± 0.1 mm accuracy
Description
Fastest, most Accurate and most Reliable Linac commissioning and
regular QA
Quality beam scanning is the cornerstone for treatment planning
and delivery accuracy. The Blue Phantom², with its scanning software myQA
Accept, is the leading water phantom solution for radiation therapy (RT) beam
scanning. The system’s unique design facilitates faster and more accurate
commissioning of RT treatment systems which is fundamental for safer patient
treatments.
The latest Blue Phantom2 is based on
over 40 years of experience during which IBA Dosimetry has been providing high
quality dosimetry equipment and services to more than 4,000 satisfied water
phantom users worldwide.
Technical specs
Exterior water tank dimensions: 675 x 645 x 560 mm
Scanning volume: 480 x 480 x 410 mm
Position resolution: 0.1 mm
Position accuracy: ± 0.1 mm
Scanning speed: 50 mm/s
Wall thickness / material: 15 mm / acrylic
DOSE 1
Single Channel
High-Performance Reference Class Electrometer
Reference Class Electrometer
DOSE-1 is a portable, single channel, high-precision reference
class electrometer for measurements of absorbed dose. The device significantly
exceeds the recommendations of the IEC 60731.
Dose, dose rate, average dose rate, charge, current and dose per
monitor unit are all measured and displayed simultaneously. Up to 40 detector
specific data sets can be stored in a sensor library, including physical and
geometrical parameters.
For verification of the instrument, connecting cable, and proper
sensor operation, an electrical check source as well as leakage and bias
voltage testing are included as standard built-in features.
Description
The therapy dose meter DOSE 1 is
a reference class dose meter according to IEC 60731 with built-in electrical
check source.
Connector type: TNC triaxial threaded
Incl. Dose 1 measurement software.
Technical specs
Polarization voltage: ± 600V, programmable in steps of 1V
Leakage check: of sensor as well as extensions cable by means of a
unique built-in device
Sensors: Ion chambers, semiconductor and diamond probes
User Interface: Large back-lit graphic EL display, 320 x 240 pixels
- Highly flexible softkey interface
- Enhanced sensor library, extendible
to 40 entries by the user, via PC
- Library of 40 user definable
calibration factors
- Simultaneous readout of charge,
current, exposure and exposure rate
Software update: From PC, via RS232 serial interface
PC interface: RS232 serial interface
Service: Easy exchangeable, factory calibrated modules with
built-in test routines
Power supply: 100 - 240 V, 50/60 hz, one power cord included for
either 230 V power plug, USA, UK, Australia or China
DOSE 2
Reference class
electrometer for measurements of absorbed dose
Independent
Dual-Channel
Portable, dual-channel,
high-precision reference class
- Dual
channel
- Portable
- High
performance
- High
precision
Description
- Two
independent measurement channels
- Intuitive
touchscreen operated interface
- Simple
data export via USB
- Threshold
triggered measurement mode
- Workflow
efficiency
- Significantly
exceeds IEC 60731 and AAPM ADCL recommendations
- Accuracy
and stability
- Wide
measurement range for advanced applications
- Independent
control of applied system factor, range, and bias voltage
MatriXX ResolutionTM
Highest
resolution for IMRT & VMAT Patient QA
Highest resolution ionization
chamber detector array for independent VMAT/IMRT Patient QA and Machine QA
Outstanding Accuracy
- 50%
more data points compared to previous MatriXX detectors for highest IMRT
& VMAT measurement resolution.
- Wireless Gantry
Sensor+ enables precise QA of rotational cases and automated gantry
angle correction.
- Confidence through independent QA.
Unrivaled Efficiency
- Fast
and straightforward detector setup.
- No cables required through complete
wireless and battery-powered design.
- Efficient measurements for Patient
QA and Machine QA verification with myQA® software.
Description
MatriXX and myQA Patients is
the solution for high dose rate and rotational 2D plan verification
MatriXX is a universal
detector also suited for MachineQA
MatriXX Evolution:
Proven detector based on
more than 1500 MatriXX systems worldwide
· Combine with the miniPhantom and Gantry Angle Sensor, to attain
the most accurate measurements for verification with myQA Patients.
· Optimized for conventional, IMRT, and rotational cases delivered
in standard dose rate mode
· Also suitable for high-dose-rate cases (up to 12 Gy/min)
Technical
specs
· Sensor type: Vented parallel ion chamber
· Number of sensors:1020, arranged in a 32 × 32 grid except for the
4 corner positions
· Active measurement area: 24.4 cm × 24.4 cm
· Chamber diameter: 4.5 mm
· Chamber height: 5.0 mm
· Chamber volume: 80 mm3
· Distance between chambers: 7.62 mm (center to center)
· Nominal sensitivity: 2.4 nC/Gy
· Collection efficiency
(pulsed beam at 300 Hz - 360 Hz PRF): ≥ 99.0% at 0.3 mGy/pulse, ≥98.5% at 0.6
mGy/pulse, ≥ 97.0% at 1.1 mGy/pulse
· Dose Rate Range: 0.02 – 12 Gy/min
· Dose Rate Dependence: < ±1.0%
· Dose Range: 0 – 10 Gy
· Bias voltage: 500 ± 30 V
· Absorber material on top: 3 mm ABS Tecaran (density 1.06 g/cm3)
· Water equivalent depth: 3.1 mm
· Effective point of measurement (Peff): 3.5 mm below the surface,
indicated by engraved markers on the housing sides.
· Deviation from Linearity: ≤ 1% for dose
≥ 0.02 Gy
MatriXX FFF
Ultimate High-Dose-Rate
Solution (up to 48 Gy/min)
· Fast: High-end design for workflow efficiency, from setup to
measurement and analysis.
· Flexible: Determined for high-dose-rate (up to 48 Gy/min),
Flattening-Filter-Free, and conventional measurements.
· FFF Proven: Supports current and foreseen high-dose-rate delivery
systems including Varian, Elekta, and Siemens.