IBA DOSIMETRY SYSTEMS AND ACCESSORIES

myQA® Daily - easy, efficient, accurate by design

myQA Daily is the only solution for fast, easy, and high-quality morning Linac QA. 

The largest number of ionization chambers provides more beam data for more accurate beam quality verification.

The web-browser-based myQA Daily application allows flexible test execution from any network PC or tablet and easy access to test results.

The newest solution for daily QA

Easy - Efficient – Accurate

·         1 minute cable free setup  

·         1 test run for dose & energy   

·         1 click analysis

Compatible with all standard Linacs

Blue Phantom 2

3D Water Phantom System for

complete Linac Commissioning & QA


The Blue Phantom² embodies decades of expertise, research and experience, providing you with the best of water phantoms.

  • Precision: Unique absolute measurement technology
  • Long-term accuracy: High-precision, non-contact position sensor technology w/o non-mechanical wear
  • Positioning:  Detector positioning certified to ± 0.1 mm accuracy

Description

Fastest, most Accurate and most Reliable Linac commissioning and regular QA

Quality beam scanning is the cornerstone for treatment planning and delivery accuracy. The Blue Phantom², with its scanning software myQA Accept, is the leading water phantom solution for radiation therapy (RT) beam scanning. The system’s unique design facilitates faster and more accurate commissioning of RT treatment systems which is fundamental for safer patient treatments.

The latest Blue Phantom2 is based on over 40 years of experience during which IBA Dosimetry has been providing high quality dosimetry equipment and services to more than 4,000 satisfied water phantom users worldwide.


Technical specs

Exterior water tank dimensions: 675 x 645 x 560 mm

Scanning volume: 480 x 480 x 410 mm

Position resolution: 0.1 mm

Position accuracy: ± 0.1 mm

Scanning speed: 50 mm/s

Wall thickness / material: 15 mm / acrylic

DOSE 1

Single Channel High-Performance Reference Class Electrometer


Reference Class Electrometer

DOSE-1 is a portable, single channel, high-precision reference class electrometer for measurements of absorbed dose. The device significantly exceeds the recommendations of the IEC 60731.

Dose, dose rate, average dose rate, charge, current and dose per monitor unit are all measured and displayed simultaneously. Up to 40 detector specific data sets can be stored in a sensor library, including physical and geometrical parameters.

For verification of the instrument, connecting cable, and proper sensor operation, an electrical check source as well as leakage and bias voltage testing are included as standard built-in features.

Description

The therapy dose meter DOSE 1 is a reference class dose meter according to IEC 60731 with built-in electrical check source.

Connector type: TNC triaxial threaded

Incl. Dose 1 measurement software.

Technical specs

Polarization voltage: ± 600V, programmable in steps of 1V

Leakage check: of sensor as well as extensions cable by means of a unique built-in device

Sensors: Ion chambers, semiconductor and diamond probes

User Interface: Large back-lit graphic EL display, 320 x 240 pixels

       - Highly flexible softkey interface

       - Enhanced sensor library, extendible to 40 entries by the user, via PC

       - Library of 40 user definable calibration factors

       - Simultaneous readout of charge, current, exposure and exposure rate

Software update: From PC, via RS232 serial interface

PC interface: RS232 serial interface

Service: Easy exchangeable, factory calibrated modules with built-in test routines

Power supply: 100 - 240 V, 50/60 hz, one power cord included for either 230 V power plug, USA, UK, Australia or China

DOSE 2

Reference class electrometer for measurements of absorbed dose


Independent Dual-Channel

Portable, dual-channel, high-precision reference class

  • Dual channel
  • Portable
  • High performance 
  • High precision

Description

  • Two independent measurement channels
  • Intuitive touchscreen operated interface
  • Simple data export via USB
  • Threshold triggered measurement mode
  • Workflow efficiency
  • Significantly exceeds IEC 60731 and AAPM ADCL recommendations
  • Accuracy and stability
  • Wide measurement range for advanced applications
  • Independent control of applied system factor, range, and bias voltage

MatriXX ResolutionTM

Highest resolution for IMRT & VMAT Patient QA

Highest resolution ionization chamber detector array for independent VMAT/IMRT Patient QA and Machine QA

 Outstanding Accuracy

  • 50% more data points compared to previous MatriXX detectors for highest IMRT & VMAT measurement resolution.
  • Wireless Gantry Sensor+ enables precise QA of rotational cases and automated gantry angle correction. 
  • Confidence through independent QA.

Unrivaled Efficiency

  • Fast and straightforward detector setup. 
  • No cables required through complete wireless and battery-powered design.
  • Efficient measurements for Patient QA and Machine QA verification with myQA® software.

Description

MatriXX and myQA Patients is the solution for high dose rate and rotational 2D plan verification

MatriXX is a universal detector also suited for MachineQA

MatriXX Evolution:

Proven detector based on more than 1500 MatriXX systems worldwide

      · Combine with the miniPhantom and Gantry Angle Sensor, to attain the most accurate measurements for verification with myQA Patients.

      · Optimized for conventional, IMRT, and rotational cases delivered in standard dose rate mode 

      · Also suitable for high-dose-rate cases (up to 12 Gy/min)

 Technical specs

      · Sensor type: Vented parallel ion chamber 

      · Number of sensors:1020, arranged in a 32 × 32 grid except for the 4 corner positions 

      · Active measurement area: 24.4 cm × 24.4 cm

      · Chamber diameter: 4.5 mm

      · Chamber height: 5.0 mm

      · Chamber volume: 80 mm3

      · Distance between chambers: 7.62 mm (center to center)

      · Nominal sensitivity: 2.4 nC/Gy

      · Collection efficiency (pulsed beam at 300 Hz - 360 Hz PRF): ≥ 99.0% at 0.3 mGy/pulse, ≥98.5% at        0.6 mGy/pulse, ≥ 97.0% at 1.1 mGy/pulse

      · Dose Rate Range: 0.02 – 12 Gy/min

      · Dose Rate Dependence: < ±1.0%

      · Dose Range: 0 – 10 Gy

      · Bias voltage: 500 ± 30 V

      · Absorber material on top: 3 mm ABS Tecaran (density 1.06 g/cm3)

      · Water equivalent depth: 3.1 mm

       · Effective point of measurement (Peff): 3.5 mm below the surface, indicated by engraved markers on the housing sides.

      · Deviation from Linearity: ≤ 1% for dose ≥ 0.02 Gy

MatriXX FFF 

Ultimate High-Dose-Rate Solution (up to 48 Gy/min)

      · Fast: High-end design for workflow efficiency, from setup to measurement and analysis.

       · Flexible: Determined for high-dose-rate (up to 48 Gy/min), Flattening-Filter-Free, and conventional measurements.

      · FFF Proven: Supports current and foreseen high-dose-rate delivery systems including Varian, Elekta, and Siemens.

  • Dowloads Brochure
  • Partner